Netapp硬件检查命令
状态检查类
-
硬件检查 environment status all
DM3KH_B::*> environment status all
"environment status" is not supported: use the "system node run -node <nodename> -command environment status" command.
DM3KH_B::*> system node run -node DM3KH_B-02 -command environment status
Sensor Name State Current Critical Warning Warning Critical
Reading Low Low High High
-------------------------------------------------------------------------------------------------
PSU2 FRU GOOD
PSU1 FRU GOOD
Attention From SP DEASSERT
SP Status IPMI_HB_OK
mSATA Status OK
mSATA Pres PRESENT
init invalid --
Environment for channel 0a
Number of shelves monitored: 1 enabled: yes
Environmental failure on shelves on this channel? no
Channel: 0a
Shelf: 0
SES device path: local access: 0a.00.99
Module type: IOM12E; monitoring is active
Shelf status: normal condition
SES Configuration, shelf 0:
logical identifier=0x500a0980084fcad8
vendor identification=NETAPP
product identification=DS212-12
product revision level=0201
Vendor-specific information:
Product Serial Number: J3026EBA
Status reads attempted: 208216; failed: 0
Control writes attempted: 0; failed: 0
Shelf bays with disk devices installed:
11, 10, 9, 8, 7, 6, 5, 4, 3, 2, 1, 0
with error: none
Power Supply installed element list: 1, 2; with error: none
Power Supply information by element:
[1] Serial number: PSQ094194801315 Part number: 114-00148+F0
Type: 7D
Firmware version: 0111 Swaps: 0
[2] Serial number: PSQ094194802841 Part number: 114-00148+F0
Type: 7D
Firmware version: 0111 Swaps: 0
Voltage Sensor installed element list: 1, 2, 3, 4; with error: none
Shelf voltages by element:
[1] 5.01 Volts Normal voltage range
[2] 12.03 Volts Normal voltage range
[3] 5.00 Volts Normal voltage range
[4] 12.02 Volts Normal voltage range
Current Sensor installed element list: 1, 2, 3, 4; with error: none
Shelf currents by element:
[1] 3040 mA Normal current range
[2] 9640 mA Normal current range
[3] 2460 mA Normal current range
[4] 8820 mA Normal current range
Cooling Unit installed element list: 1, 2, 3, 4; with error: none
Cooling Units by element:
[1] 3070 RPM
[2] 2940 RPM
[3] 3000 RPM
[4] 3000 RPM
Temperature Sensor installed element list: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15; with error: none
Shelf temperatures by element:
[1] 23 C (73 F) (ambient) Normal temperature range
[2] 30 C (86 F) Normal temperature range
[3] 30 C (86 F) Normal temperature range
[4] 30 C (86 F) Normal temperature range
[5] 30 C (86 F) Normal temperature range
[6] 28 C (82 F) Normal temperature range
[7] 31 C (87 F) Normal temperature range
[8] 30 C (86 F) Normal temperature range
[9] 31 C (87 F) Normal temperature range
[10] 39 C (102 F) Normal temperature range
[11] 56 C (132 F) Normal temperature range
[12] 32 C (89 F) Normal temperature range
[13] 41 C (105 F) Normal temperature range
[14] 57 C (134 F) Normal temperature range
[15] 34 C (93 F) Normal temperature range
Temperature thresholds by element:
[1] High critical: 50 C (122 F); high warning: 47 C (116 F)
Low critical: 0 C (32 F); low warning: 5 C (41 F)
[2] High critical: 60 C (140 F); high warning: 55 C (131 F)
Low critical: 0 C (32 F); low warning: 5 C (41 F)
[3] High critical: 60 C (140 F); high warning: 55 C (131 F)
Low critical: 0 C (32 F); low warning: 5 C (41 F)
[4] High critical: 60 C (140 F); high warning: 55 C (131 F)
Low critical: 0 C (32 F); low warning: 5 C (41 F)
[5] High critical: 60 C (140 F); high warning: 55 C (131 F)
Low critical: 0 C (32 F); low warning: 5 C (41 F)
[6] High critical: 62 C (143 F); high warning: 57 C (134 F)
Low critical: 0 C (32 F); low warning: 5 C (41 F)
[7] High critical: 100 C (212 F); high warning: 90 C (194 F)
Low critical: 0 C (32 F); low warning: 5 C (41 F)
[8] High critical: 62 C (143 F); high warning: 57 C (134 F)
Low critical: 0 C (32 F); low warning: 5 C (41 F)
[9] High critical: 100 C (212 F); high warning: 90 C (194 F)
Low critical: 0 C (32 F); low warning: 5 C (41 F)
[10] High critical: 90 C (194 F); high warning: 80 C (176 F)
Low critical: 0 C (32 F); low warning: 5 C (41 F)
[11] High critical: 105 C (221 F); high warning: 100 C (212 F)
Low critical: 0 C (32 F); low warning: 5 C (41 F)
[12] High critical: 75 C (167 F); high warning: 60 C (140 F)
Low critical: 0 C (32 F); low warning: 5 C (41 F)
[13] High critical: 90 C (194 F); high warning: 80 C (176 F)
Low critical: 0 C (32 F); low warning: 5 C (41 F)
[14] High critical: 105 C (221 F); high warning: 100 C (212 F)
Low critical: 0 C (32 F); low warning: 5 C (41 F)
[15] High critical: 75 C (167 F); high warning: 60 C (140 F)
Low critical: 0 C (32 F); low warning: 5 C (41 F)
ES Electronics installed element list: 1, 2; with error: none
ES Electronics reporting element: 1
ES Electronics information by element:
[1] Serial number: 041946028837 Part number: 111-04088+D1
CPLD version: 24 Swaps: 0
[2] Serial number: 041946028659 Part number: 111-04088+D1
CPLD version: 24 Swaps: 0
Enclosure element list: 1; with error: none;
Enclosure information:
[1] WWN: 500a0980084fcad8 Shelf ID: 00
Serial number: J3026EBA Part number: 7Y42CTO1WW
Midplane serial number: 032006003316 Midplane part number: 110-00513+A0
SAS connector attached element list: 1, 2, 3; with error: none
SAS cable information by element:
[1] Internal connector
[2] Vendor: LUXSHARE-ICT
Type: MINI-SAS HD passive copper 0.5-1.0m ID: 00 Swaps: 0
Serial number: 19315 Part number: L01HE017-SD-R+A
[3] Internal connector
[4] Vendor: <N/A> (disconnected)
Type: <N/A> <N/A> <N/A> ID: <N/A> Swaps: 0
Serial number: <N/A> Part number: <N/A>
ACP installed element list: 1, 2; with error: none
ACP information by element:
[1] MAC address: D0:39:EA:13:74:56
[2] MAC address: D0:39:EA:13:65:E8
External Ethernet Connector installed element list: 1, 2; with error: none
External Ethernet Connector information by element:
[1] MAC address: D0:39:EA:13:74:58 Attached MAC address: <N/A>
Attached port: <N/A> Attached chassis: <N/A>
Attached manufacturer: <N/A>
Cable serial number: <N/A> Cable vendor name: <N/A>
Cable id: <N/A> Cable end: <N/A>
Cable technology: <N/A> Cable length: <N/A>
[2] MAC address: D0:39:EA:13:65:EA Attached MAC address: <N/A>
Attached port: <N/A> Attached chassis: <N/A>
Attached manufacturer: <N/A>
Cable serial number: <N/A> Cable vendor name: <N/A>
Cable id: <N/A> Cable end: <N/A>
Cable technology: <N/A> Cable length: <N/A>
Processor Complex attached element list: 1, 2 with error: none
SAS Expander Module installed element list: 1, 2; with error: none
SAS Expander master module: 1
Shelf mapping (shelf-assigned addresses) for channel 0a:
Shelf 0: XXX XXX XXX XXX XXX XXX XXX XXX XXX XXX XXX XXX 11 10 9 8 7 6 5 4 3 2 1 0