Netapp硬件检查命令

orange3 发布于 阅读:486 服务器存储


状态检查类

DM3KH_B::*> environment status all
  "environment status" is not supported: use the "system node run -node <nodename> -command environment status" command.

DM3KH_B::*> system node run -node DM3KH_B-02 -command environment status
Sensor Name              State          Current    Critical     Warning     Warning    Critical
                                        Reading       Low         Low         High       High
-------------------------------------------------------------------------------------------------
PSU2 FRU                                  GOOD
PSU1 FRU                                  GOOD
Attention From SP                       DEASSERT
SP Status                               IPMI_HB_OK
mSATA Status                                OK
mSATA Pres                              PRESENT
init                     invalid            --
    Environment for channel 0a
    Number of shelves monitored: 1  enabled: yes
    Environmental failure on shelves on this channel? no

    Channel: 0a
    Shelf: 0
    SES device path: local access: 0a.00.99
    Module type: IOM12E; monitoring is active  
    Shelf status: normal condition
    SES Configuration, shelf 0:
     logical identifier=0x500a0980084fcad8
     vendor identification=NETAPP  
     product identification=DS212-12
     product revision level=0201
    Vendor-specific information:
     Product Serial Number: J3026EBA
    Status reads attempted: 208216; failed: 0
    Control writes attempted: 0; failed: 0
    Shelf bays with disk devices installed:
      11, 10, 9, 8, 7, 6, 5, 4, 3, 2, 1, 0
      with error: none
    Power Supply installed element list: 1, 2; with error: none
    Power Supply information by element:
      [1] Serial number: PSQ094194801315  Part number: 114-00148+F0
          Type: 7D
          Firmware version: 0111  Swaps: 0
      [2] Serial number: PSQ094194802841  Part number: 114-00148+F0
          Type: 7D
          Firmware version: 0111  Swaps: 0
    Voltage Sensor installed element list: 1, 2, 3, 4; with error: none
    Shelf voltages by element:
      [1] 5.01 Volts  Normal voltage range
      [2] 12.03 Volts  Normal voltage range
      [3] 5.00 Volts  Normal voltage range
      [4] 12.02 Volts  Normal voltage range
    Current Sensor installed element list: 1, 2, 3, 4; with error: none
    Shelf currents by element:
      [1] 3040 mA  Normal current range
      [2] 9640 mA  Normal current range
      [3] 2460 mA  Normal current range
      [4] 8820 mA  Normal current range
    Cooling Unit installed element list: 1, 2, 3, 4; with error: none
    Cooling Units by element:
      [1] 3070 RPM
      [2] 2940 RPM
      [3] 3000 RPM
      [4] 3000 RPM
    Temperature Sensor installed element list: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15; with error: none
    Shelf temperatures by element:
      [1] 23 C (73 F) (ambient)  Normal temperature range
      [2] 30 C (86 F)  Normal temperature range
      [3] 30 C (86 F)  Normal temperature range
      [4] 30 C (86 F)  Normal temperature range
      [5] 30 C (86 F)  Normal temperature range
      [6] 28 C (82 F)  Normal temperature range
      [7] 31 C (87 F)  Normal temperature range
      [8] 30 C (86 F)  Normal temperature range
      [9] 31 C (87 F)  Normal temperature range
      [10] 39 C (102 F)  Normal temperature range
      [11] 56 C (132 F)  Normal temperature range
      [12] 32 C (89 F)  Normal temperature range
      [13] 41 C (105 F)  Normal temperature range
      [14] 57 C (134 F)  Normal temperature range
      [15] 34 C (93 F)  Normal temperature range
    Temperature thresholds by element:
      [1] High critical: 50 C (122 F); high warning: 47 C (116 F)
          Low critical:  0 C (32 F); low warning:  5 C (41 F)
      [2] High critical: 60 C (140 F); high warning: 55 C (131 F)
          Low critical:  0 C (32 F); low warning:  5 C (41 F)
      [3] High critical: 60 C (140 F); high warning: 55 C (131 F)
          Low critical:  0 C (32 F); low warning:  5 C (41 F)
      [4] High critical: 60 C (140 F); high warning: 55 C (131 F)
          Low critical:  0 C (32 F); low warning:  5 C (41 F)
      [5] High critical: 60 C (140 F); high warning: 55 C (131 F)
          Low critical:  0 C (32 F); low warning:  5 C (41 F)
      [6] High critical: 62 C (143 F); high warning: 57 C (134 F)
          Low critical:  0 C (32 F); low warning:  5 C (41 F)
      [7] High critical: 100 C (212 F); high warning: 90 C (194 F)
          Low critical:  0 C (32 F); low warning:  5 C (41 F)
      [8] High critical: 62 C (143 F); high warning: 57 C (134 F)
          Low critical:  0 C (32 F); low warning:  5 C (41 F)
      [9] High critical: 100 C (212 F); high warning: 90 C (194 F)
          Low critical:  0 C (32 F); low warning:  5 C (41 F)
      [10] High critical: 90 C (194 F); high warning: 80 C (176 F)
          Low critical:  0 C (32 F); low warning:  5 C (41 F)
      [11] High critical: 105 C (221 F); high warning: 100 C (212 F)
          Low critical:  0 C (32 F); low warning:  5 C (41 F)
      [12] High critical: 75 C (167 F); high warning: 60 C (140 F)
          Low critical:  0 C (32 F); low warning:  5 C (41 F)
      [13] High critical: 90 C (194 F); high warning: 80 C (176 F)
          Low critical:  0 C (32 F); low warning:  5 C (41 F)
      [14] High critical: 105 C (221 F); high warning: 100 C (212 F)
          Low critical:  0 C (32 F); low warning:  5 C (41 F)
      [15] High critical: 75 C (167 F); high warning: 60 C (140 F)
          Low critical:  0 C (32 F); low warning:  5 C (41 F)
    ES Electronics installed element list: 1, 2; with error: none
    ES Electronics reporting element: 1
    ES Electronics information by element:
      [1] Serial number: 041946028837  Part number: 111-04088+D1
          CPLD version: 24  Swaps: 0
      [2] Serial number: 041946028659  Part number: 111-04088+D1
          CPLD version: 24  Swaps: 0
    Enclosure element list: 1; with error: none;
    Enclosure information:
      [1] WWN: 500a0980084fcad8  Shelf ID: 00
          Serial number: J3026EBA  Part number: 7Y42CTO1WW
          Midplane serial number: 032006003316  Midplane part number: 110-00513+A0
    SAS connector attached element list: 1, 2, 3; with error: none
    SAS cable information by element:
      [1] Internal connector
      [2] Vendor: LUXSHARE-ICT
          Type: MINI-SAS HD passive copper 0.5-1.0m  ID: 00  Swaps: 0
          Serial number: 19315  Part number: L01HE017-SD-R+A
      [3] Internal connector
      [4] Vendor: <N/A> (disconnected)
          Type: <N/A> <N/A> <N/A>  ID: <N/A>  Swaps: 0
          Serial number: <N/A>  Part number: <N/A>
    ACP installed element list: 1, 2; with error: none
    ACP information by element:
      [1] MAC address: D0:39:EA:13:74:56
      [2] MAC address: D0:39:EA:13:65:E8
    External Ethernet Connector installed element list: 1, 2; with error: none
    External Ethernet Connector information by element:
      [1] MAC address: D0:39:EA:13:74:58  Attached MAC address: <N/A>
          Attached port: <N/A>  Attached chassis: <N/A>
          Attached manufacturer: <N/A>
          Cable serial number: <N/A>  Cable vendor name: <N/A>
          Cable id: <N/A>  Cable end: <N/A>
          Cable technology: <N/A>  Cable length: <N/A>
      [2] MAC address: D0:39:EA:13:65:EA  Attached MAC address: <N/A>
          Attached port: <N/A>  Attached chassis: <N/A>
          Attached manufacturer: <N/A>
          Cable serial number: <N/A>  Cable vendor name: <N/A>
          Cable id: <N/A>  Cable end: <N/A>
          Cable technology: <N/A>  Cable length: <N/A>
    Processor Complex attached element list: 1, 2 with error: none
    SAS Expander Module installed element list: 1, 2; with error: none
    SAS Expander master module: 1

    Shelf mapping (shelf-assigned addresses) for channel 0a:
      Shelf   0: XXX XXX XXX XXX XXX XXX XXX XXX XXX XXX XXX XXX  11  10   9   8   7   6   5   4   3   2   1   0

netapp